PV Cable PV1-F 6mm2 1500V DC Single Core XLPE Insulated Solar Wire
1500V pv1 f 1x6mm2
,Single Core pv1 f 1x6mm2
,6mm2 pv cable
PV Cable PV1-F 6mm² 1500V DC Single Core XLPE Insulated Solar Wire
Core specs at a glance
| Cross section | 6 mm² |
| Conductor resistance | ≤3.39 Ω/km (20°C) |
| Insulation thickness | 0.7 mm |
| Outer diameter | 7.3 ±0.2 mm |
| Current rating (30°C ambient) | 70 A |
| Temperature range | -40°C to +90°C |
| Max short-circuit temp (5s) | 250°C |
| Test voltage | 6.5 kV AC (5 min) |
| Halogen free | Yes (IEC 60754-1) |
| UV resistance | Yes, UV stabilized |
What this cable is for
6 mm² PV1‑F wire handles higher current than 4 mm² – suitable for longer strings, combiner box feeders, or inverters with 60A+ input. Rated at 1500V DC, it works in large commercial and utility‑scale solar farms where system voltage exceeds 1000V.
The XLPE insulation stays flexible down to -40°C and resists cracking under repeated bending. Tinned copper conductor prevents galvanic corrosion when paired with aluminum lugs or MC4 connectors in outdoor environments.
Key points installers check
-
1500V DC rated – fully compatible with modern high‑voltage string inverters (Sungrow, Huawei, SMA).
-
6 mm² carries 70A – reduces voltage drop over long runs (e.g., 100m string).
-
Single core – available in black or red for polarity identification.
-
TUV certified – traceable certificate per EN50618.
-
No halogen – low smoke, non‑toxic fumes in fire per IEC 61034.
Typical applications
-
String wiring for 1500V DC systems (up to 30 panels in series)
-
Feeder cables from combiner box to DC distribution cabinet
-
Single‑core replacement for damaged array wiring
-
Off‑grid battery banks (charging circuits with 60A+ current)
Not for AC secondary wiring inside buildings.

FAQ
Q: Can I use 6 mm² PV1‑F with MC4 connectors?
Yes. Most 1500V rated MC4 connectors accept 4–6 mm² cable. Use a crimping tool with the correct die (2.5–6 mm²).
Q: Difference between PV1‑F and H1Z2Z2‑K for 6 mm²?
H1Z2Z2‑K has double insulation and higher abrasion resistance. For 1500V systems, both pass EN50618. PV1‑F is lighter and slightly cheaper.
Q: What’s the maximum string length for 6 mm² at 1500V?
At 70A and 2% voltage drop – roughly 80 meters (one way) for copper. Run your own calc using ambient temperature and local code.
Q: Is the conductor pure copper?
Yes. Tinned electrolytic copper (99.99%).
Q: Can I bury this cable directly?
Yes, if rated IP68 and protected from mechanical damage. Use conduit in rocky soil.