Mica High Temperature Cable Industrial Grade Heat Resistant Transmission Solution

Mica High Temperature Cable Industrial Grade Heat Resistant Transmission Solution
country of origin
china
Brand Name
F.T
certificate
CE,VDE,SO 9001
PRODUCT MODEL
high temperature cable
MOQ
1000
unit price
usd 0.25 ~ 1.5 / meter
payment method
L/C,D/A,D/P,T/T,Western Union
Supply Capacity
800–1500 kilometers per month
Product Details
Highlight:

Mica High Temperature Cable

,

600V High Temperature Cable

,

300V mica tape cable

Product Name: High-Temperature Mica Cable
Conductor: Stranded Copper
Insulation: Mica Tape
Rated Voltage: 300V / 600V
Temperature Rating: High-temperature Resistant
Application: Industrial Heating, Furnaces, Fire-resistant Circuits
Product Description
Detailed Specifications & Features

High-Temperature Mica Cable – Industrial-Grade Heat-Resistant Transmission Solution

Product Positioning & Technical Overview

This product series utilizes high-purity fluorophlogopite (synthetic mica) tape as the primary insulation medium, reinforced externally with a continuous fiberglass braid to form a composite insulation structure that combines rigidity with flexibility. The inherent layered silicate crystal structure of mica effectively suppresses electric arc tracking and carbonization path formation, enabling stable dielectric performance across an extreme temperature range of 600°C to 1000°C.

This cable is more than a simple "heat-resistant conductor"—it is a fire-integrity power transmission assembly engineered for active fire protection. In the event of a fire, the insulation layer neither melts nor drips, nor releases toxic smoke. Under standard flame conditions, it maintains emergency power circuit continuity for a critical duration, buying precious time for personnel evacuation and equipment shutdown procedures.

Structural Layer Diagram

Layer-by-Layer Functional Breakdown:

  1. Current-Carrying Core: Stranded or solid conductor, with copper-based or nickel-based material selection based on temperature rating, ensuring efficient power transmission with low resistivity.

  2. Functional Insulator: Synthetic mica tape precision-wrapped around the conductor at a minimum overlap rate of 55% , forming a dense mineral insulation barrier—the "fire-resistant soul" of the cable.

  3. Armor Protection Layer: High-count alkali-free fiberglass braid with coverage density ≥90%, providing not only mechanical scratch protection during installation but also securing the mica tape in position and preventing loosening under high temperatures.

  4. Surface Treatment Layer (optional): Impregnated with specialized high-temperature silicone resin or PTFE emulsion for enhanced moisture resistance, anti-fungal properties, and chemical spray resistance.

Mica High Temperature Cable Industrial Grade Heat Resistant Transmission Solution

Key Technical Specifications

Parameter Specification Data
Rated Temperature 350°C ~ 1000°C (grade-dependent)
Ambient Temperature Range Long-term: -60°C ~ 500°C; Special grades: 600°C ~ 1000°C
Rated Voltage Standard: 300V / 600V; Multi-layer reinforced insulation: up to 1000V
Conductor Material Annealed bare copper / Nickel-plated copper / Pure nickel
Conductor Cross-Section 0.25 mm² ~ 125 mm² (AWG 26 ~ 4/0)
Core Count 1 ~ 12 cores
Primary Insulation High-purity fluorophlogopite mica tape + Alkali-free fiberglass composite
Outer Sheath/Braid Fiberglass braid (optional silicone resin or PTFE coating)
Dielectric Strength AC 1000V / 50Hz, leakage current <0.25mA (3m test segment)
Insulation Resistance DC 500V megger test, ≥100MΩ (minimum, 3m length)
Fire Integrity ≥90 min continuous energization under 750°C–1000°C flame (fuse intact)
Conductor DC Resistance Complies with GB/T 3956 requirements, ≤0.5Ω/M/3m (cross-section dependent)
Bending Cycle Life 300g load, ±90° flex, 6 cycles/min, >3000 cycles without open circuit
Compliance Standards GB/T 19666-2019; IEC 60331 (fire resistance); UL 5108; BS 6387 Categories C/W/Z

Typical Application Scenarios

Mica High Temperature Cable Industrial Grade Heat Resistant Transmission Solution

  • Ferrous Metallurgy & High-Temperature Kilns: Deployed in blast furnace hot blast stoves, reheating furnaces, coke oven temperature measurement devices, and continuous caster high-current transmission systems—directly exposed to furnace body radiant heat and molten splash.

  • Petrochemical & Gas Processing: Installed in cracking units, hydrotreating reactors, and oil/gas wellhead control cabinets—meeting both intrinsic safety explosion-proof requirements and extreme thermal radiation protection needs.

  • Power & Energy Systems: Nuclear reactor containment instrumentation circuits, thermal power plant boiler burner controls, hydroelectric excitation systems, and other critical redundancy channels.

  • Aerospace & Defense Equipment: Rocket engine ignition wiring (verified to maintain structural integrity for 45 seconds under 1800°C transient thermal shock), engine compartment instrumentation harnesses.

  • New Energy Vehicle High-Voltage Platforms: Battery pack internal module connection cables, drive motor lead wires, and high-voltage DC charging socket heat-resistant sheaths—adapting to the stringent thermal management constraints within PACK assemblies.

  • Life Safety Systems: Fire pumps, smoke exhaust fans, emergency evacuation lighting, and fire alarm controller trunk circuits in high-rise buildings.

  • Commercial & Household Heating Appliances: Internal lead wires for high-power commercial ovens, electric water heating boilers, radiant heating tubes, and lighting fixtures.

  • Marine & Offshore Engineering: Specialized wiring scenarios in drilling platforms and ship engine rooms characterized by high temperature, high humidity, and confined spaces.

FAQ

Q1: How do I select the appropriate temperature rating for my specific application?

Selection should be based on the long-term steady-state operating temperature of the equipment, with an additional 20%–30% safety margin to cover instantaneous overload or fault temperature rise. For example: household ovens with a normal internal temperature of 250°C should use 350°C-rated cables; lithium battery thermal runaway protection scenarios are recommended to directly select 800°C+ grade solutions.

Q2: What are the practical engineering differences between synthetic mica and natural mica?

Synthetic fluorophlogopite mica (melting point up to 1375°C) offers superior flexural resistance and high-temperature volume resistivity, making it suitable for dynamic bending or frequent vibration environments. Natural phlogopite/muscovite mica (temperature limit approximately 750°C–830°C) is more cost-effective but relatively brittle, suitable only for fixed installation without vibration.

Q3: What are the easily overlooked installation precautions?

Because the mica insulation layer is a mineral-pressed material, rough pulling, heavy stepping, and sharp-angle bending must be avoided. Stripping operations should use specialized circular cutting tools to prevent scratching the mica tape layer. When passing through metal perforations, protective bushings or sleeves must be installed. Storage environments must remain dry and well-ventilated to prevent moisture absorption that could temporarily degrade insulation resistance.

Q4: Can this cable be used in high-voltage circuits above 600V?

Standard single-layer mica tape wrapping has a safe voltage margin designed for the 600V class. For applications requiring 1000V or higher, a double-layer mica tape separation or mica + silicone rubber composite insulation structure is required. For high-voltage applications, it is strongly recommended to confirm operating conditions with the manufacturer's technical department.

Contact us today for bulk pricing, custom lengths, and fast shipping.

📧 Email:sale@ftcable.com
📞 Phone: +86 13892838980

 

 

Related Products
Contact Us
You Can Contact Us At Anytime