1awg 2awg 3awg 4awg 6awg 8awg 10awg Silicone Power Extension Inverter Cable Automotive Battery Connect Cable with Ring Terminal

1awg 2awg 3awg 4awg 6awg 8awg 10awg Silicone Power Extension Inverter Cable Automotive Battery Connect Cable with Ring Terminal
country of origin
china
Brand Name
F.T
certificate
CE
PRODUCT MODEL
Battery Connect Cable with Ring Terminal
MOQ
1000
unit price
1.15-11.35
payment method
D/A,D/P,T/T
Supply Capacity
800–1500 kilometers per month
Product Details
Highlight:

silicone power extension cable

,

inverter battery connect cable

,

automotive cable with ring terminal

Rated Voltage: 600V
Size: 1AWG 2AWG 3AWG 4AWG 6AWG 8AWG 10AWG 12AWG
Conductor Material: Tinned Copper ( Or As Request )
Insulation Material: Silicone
Working Temperature: -60℃-200℃
Jacket: Silicone
Application: Car, Automotive, Solar, Marine, Boat, RV, Motor
Optional Length: 20cm /30cm /50cm /80cm /100cm /150cm /200cm /300cm /500cm
Product Description
Detailed Specifications & Features

This product is a silicone-insulated, high-current power connection cable with ring terminals pre-crimped at both ends. It is specifically designed for high-current DC transmission between inverters and battery packs, as well as for connecting batteries in cars, motorhomes and boats, and for wiring energy storage systems. Available in seven wire gauges—1 AWG, 2 AWG, 3 AWG, 4 AWG, 6 AWG, 8 AWG and 10 AWG—it covers the full range of requirements, from small-to-medium-power auxiliary circuits to high-power inverter main circuits.

The cables feature tinned copper conductors and a silicone rubber insulation layer, offering excellent resistance to high and low temperatures (–60 °C to +180 °C), high flexibility and resistance to ageing, making them suitable for use in engine compartments, outdoors and in high-vibration environments.

1awg 2awg 3awg 4awg 6awg 8awg 10awg Silicone Power Extension Inverter Cable Automotive Battery Connect Cable with Ring Terminal

Key Features

Silicone Insulation – A Reliable Choice for Harsh Environments
The silicone rubber insulation is the key advantage that sets this product apart from standard PVC cables. Silicone material retains its flexibility and electrical performance across a wide temperature range of –60 °C to +180 °C (up to 200 °C for certain models), unlike PVC, which becomes hard and brittle at low temperatures or softens and deforms at high temperatures. It is also halogen-free (IEC 60754-1), flame-retardant (IEC 60332-1-2) and offers excellent resistance to ozone, UV radiation, oil and chemical corrosion. This makes it an ideal choice for engine compartment wiring, high-temperature areas within inverter cabinets and outdoor photovoltaic energy storage systems.

Tinned copper conductor – a balance between conductivity and corrosion resistance
The conductor utilises tinned copper strands, with a stranding configuration compliant with IEC 60228 Class 5 or DIN VDE 0295 Class 5 standards, striking a balance between high current-carrying capacity and installation flexibility. The tin-plated layer effectively prevents oxidation and corrosion of the copper conductor in damp and salt-fog environments, significantly extending the long-term reliability of terminal connections, making it particularly suitable for marine, coastal and outdoor applications.

Pre-crimped ring terminals – ready to use, reducing contact resistance
The ring terminals at both ends are produced using a specialised crimping process (not soldering), ensuring an airtight cold-welded connection between the conductor and the terminal, resulting in extremely low contact resistance and high mechanical strength. The terminal bore sizes are compatible with mainstream battery terminals (M6, M8, M10, etc.), whilst the flat contact surface design ensures maximum electrical contact area with battery terminals or inverter terminals. Users do not need to crimp the terminals themselves; they are ready for installation straight out of the box, significantly reducing the risk of overheating and faults caused by poor crimping.

AWM STANDARD SPECIFICATION PARAMETER SHEET
Specifications
(AWG)
Copper min
share (compos.NOmm)
Sectional
Area(mm²)
Diameter
(mmm)
Jacket
thickness
Orerall
diameter (mm)
Max.cond.
resistance (ΩKM,20-C)
4/0 AWG
21300/0.08TC
107.20
13.49
2.03
19.50
0.02
3/0 AWG
16900/0.08TC
85.01
12.01
2.03
18.50
0.22
2/0 AWG
13400/0.08TC
67.43
10.70
2.03
16.80
0.28
1/0 AWG
10600/0.08TC
53.49
9.51
2.03
15.50
0.35
1AWG
8400/0.08TC
42.41
8.47
2.03
14.50
0.44
2AWG
6600/0.08TC
33.62
7.51
1.53
12.50
0.56
3AWG
5300/0.08TC
26.67
6.73
1.53
11.80
0.70
4AWG
4200/0.08TC
21.15
5.99
1.53
11.00
0.88
5AWG
3300/0.08TC
16.77
5.31
1.53
10.50
1.11
6AWG
2610/0.08TC
13.30
4.72
1.53
9.80
1.41
7AWG
2090/0.08TC
10.55
4.22
1.53
9.30
1.76
8AWG
1660/0.08TC
8.37
3.76
1.53
8.80
2.23
9AWG
1300/0.08TC
6.63
3.33
1.15
7.50
2.88
10AWG
1040/0.08TC
5.26
2.98
1.15
7.20
3.62
11AWG
820/0.08TC
4.17
2.65
0.76
5.20
4.57
12AWG
650/0.08TC
3.31
2.36
0.76
4.90
5.75
13AWG
520/0.08TC
2.63
2.11
0.76
4.60
7.26
14AWG
410/0.08TC
2.08
1.87
0.76
4.40
9.25
15AWG
325/0.08TC
1.65
1.67
0.76
4.20
11.60
16AWG
260/0.08TC
1.31
1.49
0.76
4.00
14.70
17AWG
205/0.08TC
1.04
1.32
0.76
3.80
18.50
18AWG
163/0.08TC
0.82
1.18
0.76
3.70
13.50
19AWG
130/0.08TC
0.65
1.05
0.76
3.60
29.50
20AWG
103/0.08TC
0.52
0.94
0.76
3.50
37.40
21AWG
82/0.08TC
0.41
0.84
0.76
3.40
46.90
22AWG
64/0.08TC
0.33
0.74
0.76
3.30
59.40
23AWG
52/0.08TC
0.26
0.67
0.76
3.20
74.50
24AWG
41/0.08TC
0.20
0.59
0.76
2.40
94.20
25AWG
32/0.08TC
0.16
0.52
0.76
2.30
119.00
26AWG
26/0.08TC
0.13
0.47
0.76
2.20
150.00
27AWG
20/0.08TC
0.10
0.41
0.40
1.40
188.00
28AWG
16/0.08TC
0.08
0.37
0.40
1.30
239.00
29AWG
12/0.08TC
0.06
0.32
0.40
1.20
297.00
30AWG
10/0.08TC
0.05
0.29
0.40
1.10
381.00

Typical Applications

Connecting the Inverter to the Battery Pack
The core application of this series of cables is the transmission of power from the battery to the inverter on the DC side. The required cable gauge varies significantly depending on the inverter’s power rating and the system voltage (12V/24V/48V). For example, when transmitting 2,400 W of power in a 12 V system, the current at the battery end can exceed 200 A, requiring 2 AWG or thicker cable to control voltage drop and temperature rise. The high-temperature resistance of the silicone insulation allows the cable to operate safely in high-temperature areas near the inverter.

Automotive/Motorhome/Marine Battery Systems
Within vehicle electrical systems, this product is suitable for applications such as connecting the starter battery to the auxiliary battery, powering high-power winches, and supplying power to on-board inverters. The combination of tinned copper conductors and silicone insulation enables it to withstand high temperatures and vibrations in the engine compartment, as well as salt spray corrosion in coastal environments. The pre-crimped ring terminals can be fitted directly onto standard battery terminal bolts (M6/M8/M10); for installation torque, please refer to the battery or equipment manual (typical value: 5 N·m).

Energy Storage Systems (ESS/BESS)
In residential and commercial/industrial energy storage systems, this cable is used for parallel connections between battery clusters and for DC busbar connections from battery clusters to the PCS (Power Conversion System). The halogen-free and flame-retardant properties of the silicone rubber insulation meet fire safety requirements for indoor installation, whilst its wide temperature range performance is suited to the internal environment of containerised energy storage cabinets.

1awg 2awg 3awg 4awg 6awg 8awg 10awg Silicone Power Extension Inverter Cable Automotive Battery Connect Cable with Ring Terminal

Selection Guide


Step 1: Determine the continuous current
Calculate the current based on the equipment’s maximum continuous power and the system’s minimum operating voltage. For inverter applications, use the maximum DC input current adjusted for inverter efficiency or the maximum DC current specified by the manufacturer, rather than simply dividing the power by the nominal voltage.

Step 2: Apply a safety factor
For continuous loads (operating continuously for more than 3 hours), it is recommended to determine the minimum current-carrying capacity requirement of the cable as the actual current multiplied by 1.25.

Step 3: Verify Voltage Drop
When routing cables over long distances, voltage drop may become a decisive factor in selection. It is recommended that the design target be no more than 2%–3% of the system voltage. The formula for calculating voltage drop is ΔV = I × R × 2L (where 2L is the round-trip path length). If the cable meets the current-carrying capacity requirements but the voltage drop exceeds the limit, a larger cable gauge must be selected.

Step 4: Confirm Terminal Sizes
Select the appropriate ring terminal bore size based on the thread specifications (M6/M8/M10) of the battery or equipment terminals. During installation, ensure that the flat contact surface of the terminal makes full contact with the terminal post and tighten to the torque specified by the equipment manufacturer.

Installation and Safety Precautions
Polarity verification: Before connecting to the inverter, always use a multimeter to verify that the polarity of the battery’s positive and negative terminals matches that of the inverter terminals. Inverters typically do not feature reverse connection protection; reverse connection will result in permanent damage to the equipment.

Overcurrent protection: Install a DC-rated fuse or circuit breaker on the battery positive circuit as close as possible to the battery terminals. The fuse rating should be higher than the maximum load current but lower than the cable’s current-carrying capacity.

Terminal Tightening: Ring terminals must lie flat against the terminal posts and be tightened to the torque specified in the equipment manual (typically 2–5 N·m, depending on the terminal specification). Insufficient torque will result in increased contact resistance and heat generation, whilst excessive torque may damage the terminals or terminal posts.

Cable Protection: Avoid routing cables near sharp edges, high-temperature heat sources or moving parts. Although silicone insulation offers excellent temperature resistance, its mechanical strength is lower than that of materials such as cross-linked polyolefin; it is therefore recommended to fit a protective sleeve when passing through metal openings.

The use of CCA wire is prohibited: Copper-clad aluminium (CCA) conductors have a significantly lower current-carrying capacity than pure copper for the same wire gauge, which can lead to severe overheating. Please ensure that the conductors in this product are made of tinned pure copper; CCA must not be used as a substitute.