F.T Cable THHN 12 AWG Stranded Copper Building Wire 600 V 90 C for Branch Circuit and Feeder Pulls in Conduit and EMT

F.T Cable THHN 12 AWG Stranded Copper Building Wire 600 V 90 C for Branch Circuit and Feeder Pulls in Conduit and EMT
country of origin
china
Brand Name
F.T
certificate
CE,VDE,SO 9001,ul
PRODUCT MODEL
thhn cable
MOQ
1000
unit price
usd 0.8 ~ 1.28/ meter
payment method
L/C,D/A,D/P,T/T,Western Union
Supply Capacity
800–1500 kilometers per month
Product Details
Highlight:

THHN 12 AWG stranded copper wire

,

600V 90C building wire

,

THHN cable for conduit and EMT

Rated Voltage: 600V
Size: 8 10 12 14 16 AWG
Jacket: PVC
Application: Building
Model Number: Thhn Cable
Color: Customized Colors
Conductor: Copper
Product Description
Detailed Specifications & Features

THHN 12 AWG Stranded Copper Building Wire, 600 V, 90 C Dry

A single conductor for branch circuits and feeders pulled in conduit: 19 strand annealed copper, PVC insulation, nylon jacket, 600 V, 90 C dry location.

The nylon jacket is why this wire survives a real pull. It takes the abrasion at couplings and box edges that turns a long EMT run into nicked insulation and a failed megger three weeks later.

Rated 12 AWG: NEC Table 310.16 lists 20 A, 25 A and 30 A in the 60 C, 75 C and 90 C columns, and NEC 240.4(D) caps the overcurrent device at 20 A for this size. That is the standard 20 A branch circuit, stated the way an inspector reads it.

THHN building wire in black, white, green and red, stripped ends showing stranded copper conductors

12 AWG, 10 AWG and other sizes in the standard colors. Stripped ends show the 19 strand copper and the PVC plus nylon wall.

Specifications

Type: THHN, thermoplastic high heat-resistant nylon coated, single conductor building wire

Voltage rating: 600 V

Size and stranding: 12 AWG, 19 strand (solid 12 AWG also available; series covers 14, 12 and 10 AWG)

Conductor: annealed copper to ASTM B3 and B8

Insulation: flame retardant heat resistant PVC, nominal 0.015 in (0.38 mm)

Jacket: polyamide (nylon), nominal 0.004 in (0.10 mm)

Overall diameter: 0.127 in (3.23 mm) stranded, 0.120 in (3.05 mm) solid

Net weight: 23 lb per 1000 ft, so a 500 ft coil is about 11.5 lb

Temperature rating: 90 C dry location; a wet location rating applies only where the print legend carries the THWN or THWN-2 designation

Ampacity: 20 A at 60 C, 25 A at 75 C, 30 A at 90 C per NEC Table 310.16; overcurrent device limited to 20 A by NEC 240.4(D)

Standards: construction to UL 83, conductor to ASTM B3 and B8, installation to NEC Article 310, VW-1 flame marking to UL 2556

Put-up: 500 ft coil, 2500 ft reel, or cut to length

The three layers

Build of THHN 12 AWG stranded wire: nylon jacket, PVC insulation, 19 strand annealed copper, overall diameter 0.127 inch

Stripped back: nylon jacket, PVC insulation, 19 strand copper. Nominal dimensions per published 12 AWG stranded data.

  • Annealed copper, 19 strand: 19 wires bend more easily than a 7 wire build, so a pull through offsets and couplings loads each strand evenly and the end does not splay at the lug.
  • PVC insulation, 0.015 in: the UL 83 nominal wall for 12 AWG. It carries both the 600 V dielectric margin and the 90 C conductor rating; the flame retardant package in the compound is what allows the VW-1 marking on the jacket.
  • Nylon jacket, 0.004 in: four mils that do the work on site. Low friction, high abrasion resistance, and rated Gas and Oil Resistant II, so a machine shop pull does not swell the insulation.

Close up of black THHN wire end showing the printed legend and 19 stranded copper conductors

Print legend carries the type, size, temperature rating and flame marking; the cut end shows the strand count.

Where it goes

Commercial ceiling and EMT runs: between tray and fixtures, multiple conductors in one raceway, threaded coupling ends that scuff anything soft. The nylon layer is what meets the coupling.

Residential branch circuits: 20 A circuits from the panel to receptacles and lighting, in conduit or in framed walls.

Panel to junction pulls: tight radii inside an enclosure. 19 strand routes around corners without the spring back of solid wire and crimps cleanly into lugs.

Control wiring in dry enclosures: 24 V and 120 V control circuits where cabinet temperature near a drive can sit above 60 C, which leaves margin on a 90 C conductor.

Machine tool leads where MTW is specified: only where the jacket legend also carries the MTW designation, since plain THHN is not MTW.

Coil of black THHN building wire on a light background

Standard put-up is a 500 ft coil; 2500 ft reels and cut lengths are also supplied.

Red THHN building wire coil with the cut end showing the stranded copper conductor

Color is part of the order, not an afterthought: black, white, red, green and blue are standard, other colors per the color code on request. The cut end shows the strand bundle and the jacket wall in one view.

Standards and tests

UL 83: thermoplastic insulated wires and cables. Structure and dimensions, insulation and jacket thickness, voltage withstand, insulation resistance, mechanical properties, heat and moisture resistance.

ASTM B3: soft or annealed copper wire, covering the individual strands.

ASTM B8: concentric lay stranded conductors; 12 AWG stranded is a 19 wire construction.

UL 2556: the VW-1 vertical flame test method behind the flame marking on the jacket.

NEC Article 310: ampacities and conditions of use, including Table 310.16 and the correction and adjustment factors in 310.15.

NEC 240.4(D): the small conductor overcurrent limits that govern 14, 12 and 10 AWG.

ICEA S-95-658 and NEMA WC70: general requirements for power cable construction, marking and packaging.

RoHS: restricted substances, relevant for European destinations and for buyers who carry the requirement through their own supply chain.

Each production length is continuity and voltage tested, and the print legend carries size, temperature rating and the VW-1 marking. Type test reports are supplied when the order scope includes them.

Choosing the right conductor

Dry locations in conduit: THHN is the right call. For wet locations or buried runs, confirm the THWN or THWN-2 designation on the legend, otherwise specify XHHW-2.

20 A branch circuit: 12 AWG copper. Do not read the 30 A figure in the 90 C column as permission for a 30 A breaker; 240.4(D) does not allow it.

Panel work and terminations: stranded 19 bends and crimps more cleanly. Solid is cheaper and pulls better in long straight runs.

More than three current carrying conductors in one raceway: apply the adjustment factors in NEC 310.15(C)(1) before checking the ampacity, and do not read the table value straight.

Machine tool or equipment builder: ask for MTW and oil resistance ratings on the legend; THHN alone does not satisfy that scope.

Low smoke or halogen free project requirement: PVC insulation will not comply; move to an XLPE or LSZH construction.

FAQ

Can I use THHN outdoors or in wet locations?

Only if the print legend shows a dual rating such as THWN or THWN-2. Plain THHN is a 90 C dry location conductor, and wet location use requires the W rating on the jacket.

Is 12 AWG correct for a 20 A breaker?

Yes. 12 AWG copper is the standard conductor for a 20 A branch circuit, and 240.4(D) caps the overcurrent device at 20 A for this size. The 30 A in the 90 C column of Table 310.16 is for derating calculations, not for upsizing the breaker.

Solid or stranded for panel work?

Stranded 19 is easier to route inside a panel and holds up to repeated bending at terminals. Solid is cheaper and pulls well in long straight conduit. Both are 12 AWG and both are UL 83 constructions.

What is the outside diameter, and will it fit my conduit?

0.127 in for 12 AWG stranded and 0.120 in for solid. Conduit fill is calculated from those diameters under NEC Chapter 9, Table 1, with 40 percent fill for three or more conductors.

Do you supply 500 ft coils or 2500 ft reels?

Both, plus cut lengths. A 500 ft coil of 12 AWG stranded weighs about 11.5 lb, which is one person up a ladder.

Is this wire UL listed?

The construction follows UL 83 and the conductor follows ASTM B3 and B8. UL listing status and the file number are stated on the order documents for the specific put-up; ask for the label artwork before the order if your inspector requires it.

Notes

Dimensions and weights are nominal and follow published 12 AWG stranded THHN data. Ampacities are from NEC Table 310.16 with the 240.4(D) limit applied. The photographs on this page are product photographs; the build diagram is an illustration prepared for the product, not a photograph of a specific spool.