8.7 15KV YJV22 High Voltage Cable 3 Core 3 X 35/50/70/95/120/150/185/240/300 Power Cable
8.7 15KV YJV22 High Voltage Cable 3 Core 3 X 35/50/70/95/120/150/185/240/300 Power Cable
country of origin
Shaanxi, China
Brand Name
F.T
certificate
CE,VDE,SO 9001
PRODUCT MODEL
YJV22
MOQ
1000
unit price
usd 3 ~ 20/ meter
payment method
L/C,D/A,D/P,T/T
Supply Capacity
800–1500 kilometers per month
Product Details
Highlight:
High Voltage Cable 15KV
,8.7KV High Voltage Cable
,3 X 35 high voltage electric cable
Conductor Material:
Copper
Insulation Material:
XLPE
Rated Voltage:
8.7/15kv
Size:
3*240mm2
Application:
Construction
Jacket:
PVC
Type:
Other, Medium/High Voltage
No. Of Cores:
1~6 Core
MOQ:
1000m
Hot Sale Countries:
Philippine,Yemen,Vietnam, Indonesia,Indonesia,Afr
Service:
ODM OEM Accepted
Delivery:
10-25days After Received The Prepayment
Sample:
Free
Product Description
Detailed Specifications & Features
High voltage cable YJV22 8.7/15KV 3 Core 3*35/50/70/95/120/150/185/240/300 Power Cable
Products Description
Product structure
Cable size parameters for YJV High Voltage

Applicable environment and conditions
1. Ambient temperature: the ambient temperature when laying the cable should not be less
than 0℃.
than 0℃.
2. Bending radius: single-core cable not less than 15 times the outer diameter of the cable; multi-core cable not less than 10 times the outer diameter of the cable
Scope of use
This mainly includes indoor, cable trench, pipeline, tunnel and rocky areas. This type of cable, is suitable for the backbone of circuit transmission.
This mainly includes indoor, cable trench, pipeline, tunnel and rocky areas. This type of cable, is suitable for the backbone of circuit transmission.
|
tem Name
|
Power cable
|
|
|
Coductor
|
Aluminum or Copper
|
|
|
Armoured
|
SWA(Steel Wire Armoured) / STA(Steel Tape Armoured) or Non-Armoured
|
|
|
Insulation
|
PVC/LSF/Fire Resistant
|
|
|
Cores
|
1, 2, 3, 4, 5, 3+1, 4+1, 3+2
|
|
|
Section Area
|
1.5mm2- 300mm2
|
|
|
Voltage
|
0.6/1kv 1.8/3kv 3.6/6kv 6/10kv 8.7/15kv 12/20kv 21/35kv 26/35kv
|
|
|
Jacket Color
|
Black
|
|
|
Application
|
Power region,electric transmission, distribution system and so on
|
|
|
Packing
|
Iron Or Wooden Drum
|
|
|
Delivery Detail
|
7-14 days after confirming the order
|
|
|
We can customize the size according to your requirement
|
|
|
Cable size parameters for YJV High Voltage
| Nominal cross section of conductor (mm²) | Thickness of insulation (mm) | Jacket Thickness (mm) | Approximate cable OD (mm) | Approximate cable weight (kg/km) | 20℃ conductor resistance ≤ (Ω/km) | Test Voltage A.C. kv/5min | Carrying capacity of cable (A) | |||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Cu | Al | Cu | Al | in the air | Direct burial in soil | |||||||
| Cu | Al | Cu | Al | |||||||||
| 1×1.5 | 0.7 | 1.5 | 6 | 53 | — | 12.1 | — | 3.5 | 25 | — | 35 | — |
| 1×2.5 | 0.7 | 1.5 | 6 | 68 | 53 | 7.41 | 12.1 | 3.5 | 30 | 25 | 45 | 35 |
| 1×4 | 0.7 | 1.5 | 7 | 87 | 64 | 4.61 | 7.41 | 3.5 | 45 | 35 | 60 | 50 |
| 1×6 | 0.7 | 1.5 | 7 | 110 | 73 | 3.08 | 4.61 | 3.5 | 55 | 45 | 70 | 55 |
| 1×10 | 0.7 | 1.5 | 8 | 155 | 95 | 1.83 | 3.08 | 3.5 | 75 | 60 | 95 | 75 |
| 1×16 | 0.7 | 1.5 | 9 | 220 | 120 | 1.15 | 1.91 | 3.5 | 100 | 80 | 125 | 100 |
| 1×25 | 0.9 | 1.5 | 10 | 345 | 190 | 0.727 | 1.20 | 3.5 | 140 | 115 | 160 | 130 |
| 1×35 | 0.9 | 1.5 | 12 | 424 | 207 | 0.524 | 0.868 | 3.5 | 185 | 140 | 190 | 150 |
| 1×50 | 1.0 | 1.5 | 13 | 555 | 245 | 0.387 | 0.641 | 3.5 | 210 | 170 | 225 | 180 |
| 1×70 | 1.1 | 1.5 | 14 | 770 | 336 | 0.268 | 0.443 | 3.5 | 270 | 215 | 280 | 225 |
| 1×95 | 1.1 | 1.5 | 16 | 1040 | 455 | 0.193 | 0.320 | 3.5 | 340 | 275 | 335 | 270 |
| 1×120 | 1.2 | 1.5 | 18 | 1290 | 550 | 0.153 | 0.253 | 3.5 | 400 | 320 | 380 | 305 |
| 1×150 | 1.4 | 2.0 | 21 | 1590 | 650 | 0.124 | 0.206 | 3.5 | 460 | 370 | 425 | 340 |
| 1×185 | 1.6 | 2.0 | 23 | 1944 | 804 | 0.0991 | 0.164 | 3.5 | 530 | 415 | 480 | 375 |
| 1×240 | 1.7 | 2.0 | 25 | 2510 | 1021 | 0.0754 | 0.125 | 3.5 | 625 | 490 | 555 | 435 |
| 1×300 | 1.8 | 2.0 | 34 | 3042 | 1160 | 0.0601 | 0.100 | 3.5 | 795 | 615 | 910 | 710 |
| 1×400 | 2.0 | 2.1 | 37 | 3869 | 1469 | 0.0470 | 0.0778 | 3.5 | 930 | 730 | 1050 | 820 |
| 1×500 | 2.2 | 2.2 | 41 | 4910 | 1829 | 0.0366 | 0.0605 | 3.5 | 1080 | 850 | 1190 | 940 |
| 1×630 | 2.4 | 2.3 | 45 | 6220 | 2305 | 0.0283 | 0.0469 | 3.5 | 1250 | 1000 | 1350 | 1080 |
| 1×800 | 2.6 | 2.4 | 46 | 7870 | 2910 | 0.0221 | 0.0367 | 3.5 | 1440 | 1160 | 1520 | 1220 |
| 1×1000 | 2.8 | 2.6 | 51 | 9804 | 3604 | 0.0176 | 0.0291 | 3.5 | 1630 | 1330 | 1690 | 1380 |
| Nominal cross‑sectional area of conductor | outside diameter(mm) | weight(kg/km) | Nominal cross‑sectional area of conductor | outside diameter(mm) | weight(kg/km) | Nominal cross‑sectional area of conductor | outside diameter(mm) | weight(kg/km) |
|---|---|---|---|---|---|---|---|---|
| 3×1.5 | 10.4 | 120.8 | 3×1.5+1×1.0 | 10.9 | 138.9 | 3×1.5+2×1.0 | 13.4 | 158.9 |
| 3×2.5 | 11.3 | 158.5 | 3×2.5+1.5 | 11.8 | 181.7 | 3×2.5+2×1.5 | 14.4 | 207.3 |
| 3×4 | 12.2 | 210.4 | 3×4+1×2.5 | 12.9 | 245.4 | 3×4+2×2.5 | 15.5 | 282.1 |
| 3×6 | 13.4 | 280.2 | 3×6+1×4 | 14.1 | 329.5 | 3×6+2×4 | 16.9 | 382.2 |
| 3×10 | 16.1 | 430.7 | 3×10+1×6 | 16.8 | 497.1 | 3×10+2×6 | 19.5 | 569 |
| 3×16 | 18.4 | 623.6 | 3×16+1×10 | 19.4 | 734.7 | 3×16+2×10 | 22.6 | 853.3 |
| 3×25 | 22.1 | 947.1 | 3×25+1×16 | 23.2 | 1114 | 3×25+2×16 | 26.5 | 1292 |
| 3×35 | 24.6 | 1251 | 3×35+1×16 | 25.2 | 1414 | 3×35+2×16 | 28.4 | 1590 |
| 3×50 | 27.9 | 1660 | 3×50+1×25 | 29.1 | 1919 | 3×50+2×25 | 33 | 2211 |
| 3×70 | 32.8 | 2353 | 3×70+1×35 | 34 | 2702 | 3×70+2×35 | 39.4 | 3093 |
| 3×95 | 37.1 | 3179 | 3×95+1×50 | 38.7 | 3667 | 3×95+2×50 | 44.7 | 419 |
| 3×120 | 41.2 | 3983 | 3×120+1×70 | 47.1 | 5503 | 3×120+2×70 | 46.6 | 5431 |
| 3×150 | 45.8 | 4909 | 3×150+1×70 | 50.8 | 6460 | 3×150+2×70 | 50 | 6315 |
| 3×185 | 50.9 | 6104 | 3×185+1×95 | 56.5 | 8029 | 3×185+2×95 | 56.1 | 8046 |
| 3×240 | 57.4 | 7941 | 3×240+1×120 | 57.6 | 9527 | 3×240+2×120 | 63.1 | 10377 |
| 3×300 | 63.4 | 9890 | 3×300+1×150 | 63.4 | 11690 | 3×300+2×150 | 69.8 | 12887 |
| 3×400 | 71.1 | 12585 | 3×400+1×185 | 77.2 | 15766 | 3×400+2×185 | 78.1 | 16336 |
| 4×1.5 | 11.1 | 145.7 | 4×1.5+1×1.0 | 11.8 | 165.2 | 5×1.5 | 11.9 | 171.5 |
| 4×2.5 | 12.1 | 194.3 | 4×2.5+1.5 | 12.8 | 219.3 | 5×2.5 | 13 | 231.3 |
| 4×4 | 13.2 | 261.6 | 4×4+1×2.5 | 14 | 297.6 | 5×4 | 14.2 | 314.2 |
| 4×6 | 14.5 | 352.4 | 4×6+1×4 | 15.4 | 403.9 | 5×6 | 15.6 | 426.4 |
| 4×10 | 17.6 | 547.3 | 4×10+1×6 | 18.4 | 617.7 | 5×10 | 19.1 | 666.7 |
| 4×16 | 20.1 | 799.1 | 4×16+1×10 | 21.4 | 915.9 | 5×16 | 22 | 978.8 |
| 4×25 | 24.3 | 1222 | 4×25+1×16 | 25.7 | 1397 | 5×25 | 26.6 | 1503 |
| 4×35 | 27.1 | 1626 | 4×35+1×16 | 28.1 | 1796 | 5×35 | 29.7 | 2004 |
| 4×50 | 31 | 2172 | 4×50+1×25 | 33 | 2461 | 5×50 | 34.2 | 2696 |
| 4×70 | 36.4 | 3080 | 4×70+1×35 | 38.3 | 3466 | 5×70 | 40.2 | 3825 |
| 4×95 | 41.2 | 4166 | 4×95+1×50 | 43.5 | 4682 | 5×95 | 45.8 | 5196 |
| 4×120 | 46 | 5244 | 4×120+1×70 | 48.8 | 5981 | 5×120 | 50.8 | 6513 |
| 4×150 | 50.9 | 6435 | 4×150+1×70 | 53.2 | 7163 | 5×150 | 56.5 | 8020 |
| 4×185 | 56.8 | 8034 | 4×185+1×95 | 59.6 | 9023 | 5×185 | 63.1 | 10010 |
| 4×240 | 64 | 10452 | 4×240+1×120 | 67.1 | 11691 | 5×240 | 71.1 | 13019 |
| 4×300 | 70.8 | 13017 | 4×300+1×150 | 74.2 | 14542 | 5×300 | 78.6 | 16213 |
| 4×400 | 79.6 | 16600 | 4×400+1×185 | 83.3 | 18509 | 5×400 | 88.5 | 20706 |


Application
-
Urban & Rural Power Grid ConstructionMainly used for underground power transmission lines in urban districts, towns and rural areas, including urban trunk power networks, community power supply, rural medium‑voltage power distribution systems, underground cable corridors and buried power pipelines.
-
New Energy Power Station ProjectsWidely applied in solar photovoltaic power plants, wind farms, energy storage stations. Used for medium‑voltage power collection, step‑up station connection and power transmission from power generation areas to power grids.
-
Industrial Park & Heavy‑Industry EnterprisesFor power supply of chemical plants, mining areas, steel mills, manufacturing industrial parks and large factories. Adapted to harsh environments such as buried laying, chemical corrosion and heavy‑pressure ground conditions.
-
Infrastructure & Transportation ProjectsUsed in high‑speed railways, highways, subways, tunnels, airports and ports. For power supply of supporting facilities, tunnel buried power lines and outdoor medium‑voltage distribution systems.
-
Commercial Complexes & Large Public BuildingsMedium‑voltage power distribution for large shopping malls, hospitals, schools, office buildings and stadiums, realizing stable power input for main power distribution rooms.
-
Mining & Underground Engineering ProjectsSteel tape armor provides excellent anti‑mechanical‑damage performance, suitable for buried laying in mines, underground pipe galleries and mountainous areas with complex geological conditions.
-
Water Conservancy & Municipal EngineeringPower transmission for water conservancy projects, sewage treatment plants, pumping stations and municipal underground pipe networks, resisting moisture and soil corrosion for long‑term stable operation.
Related Products
Contact Us
You Can Contact Us At Anytime